Operator’s Manual
English
TABLE OF CONTENTS
INTENDED USE.............................................................. 2
SUMMARY AND EXPLANATION.................................... 2
PRINCIPLES OF OPERATION ....................................... 2
ATTENTION LABEL ........................................................ 4
SPECIFICATIONS........................................................... 5
GETTING STARTED....................................................... 5
SETTING SUPERVISOR OPTIONS ............................. 11
SETTING OUTPUT OPTIONS ...................................... 18
SETTING PROGRAM OPTIONS .................................. 20
CUSTOMIZING THE PRINTED HEADING ................... 21
OPERATION ................................................................. 21
QUALITY CONTROL (QC)............................................ 27
OPERATING PRECAUTIONS....................................... 29
LIMITATIONS................................................................ 29
RESULTS MANAGEMENT ........................................... 30
DEFAULT SETTINGS ................................................... 32
TROUBLESHOOTING .................................................. 33
SYSTEM TESTS ........................................................... 35
MAINTENANCE ............................................................ 38
SPECIFICATIONS FOR PERIPHERALS ...................... 39
SAFETY STANDARDS ................................................. 41
INDEX ........................................................................... 42
This manual is published by International Technidyne Corporation (ITC) for use with the HEMOCHRON
Response V2.00 or above. Questions or comments regarding the contents of this manual can be directed to
the address at the back of this manual or to your ITC representative.
HEMOCHRON
®
and RxDx
®
are registered trademarks of ITC.
idms™ is a trademark of ITC.
Celite
®
is registered trademark of Celite Corporation.
©2000, 2001, 2002, 2003, 2004. This document is the copyright of ITC and must not be copied or
reproduced in any form without prior consent. ITC reserves the right to make technical improvements to
this equipment and documentation without prior notice as part of a continuous program of product
development.
Printed From ITC Intranet
Page view 0
1 2 3 4 5 6 ... 18 19

Summary of Contents

Page 1

Operator’s Manual English TABLE OF CONTENTS INTENDED USE... 2 SUMMARY AND EXPLANATION...

Page 2

10 The arrows designate the operation that will be halted if the CANCEL key is pressed. If an operation is canceled, the arrows will point to the nex

Page 3

11 Select a command by pressing the corresponding numeral key while the command is displayed. For example, if a PID or OID/PIN is to be entered using

Page 4

12 To Display the Supervisor Menu: 1. Display the second page of the main menu. 2. Press 4 to display the Enter Passcode prompt. Enter the passcode. 3

Page 5

13 Displaying the Clock The time can be displayed on the separator bar of the display panel. 1. Display the first page of the Supervisor menu. 2. Pres

Page 6

14 Specifying the Length of Time a PID will be Reused After a PID is entered, it can be displayed as a default entry for a specified number of hours.

Page 7

15 Specifying OID, PIN, and Test Permissions for an Operator Note: HRDM V. 3.0 or higher software can be used to manage operator tables. 1. Display t

Page 8

16 Specifying QC Lockouts 1. Display the second page of the Supervisor menu. 2. Press 6 to display the first page of the QC Lockout menu: 3. To speci

Page 9

17 Suppressing Results Display During a QC Test Display of the clotting time during a QC test (on the screen, printed result, and in the database) can

Page 10

18 Downloading Records Patient and QC records can be downloaded to a personal computer from the system. ITC data management software programs can be i

Page 11

19 Enabling Display of Remaining Battery Power The amount of power remaining in the battery can be displayed either as a numerical percentage or as a

Page 12

2 INTENDED USE The HEMOCHRON® Response Whole Blood Coagulation System is a dual-well microprocessor-controlled coagulation testing instrument with an

Page 14

3 The system (Figure 1) contains a dual-well patented clot detection module. User interface is through a keypad and display panel. Test results are sh

Page 15

4 After a clot forms, the instrument beeps and the clotting time is displayed on the display panel. The result is also stored in the system database w

Page 16

5 SPECIFICATIONS Specifications for the HEMOCHRON Response Whole Blood Coagulation System are listed below. Dimensions and Weight Depth 19 cm (7.5 in)

Page 17

6 Materials Provided RS232 Computer Interface Cable 1 Materials Required But Not Provided Article Quantity Electronic System Verification Tube 1 HE

Page 18

7 Connecting a Personal Computer The system can be connected to a personal computer using a standard NULL modem cable. 1. Obtain an RS232 cable (provi

Page 19

8 Prewarming The test wells can be prewarmed to 37 °C ±1.0 °C on command. On completion, 3 short beeps are emitted. Note: Refer to assay package inse

Page 20

9 Display Panel Operations such as running a test and prewarming a well can be carried out simultaneously on both wells. However, commands, prompts, a